PROJECT-OUT/AWNING WINDOWS

project-out_window_samples

PERFORMANCE CHART

TEST TYPE

RESULTS

Air Infiltration

.03 CFM @ 6.24 PSF

Maximum Water Resistance

16.5 PSF

Uniform Static Load Test
Design Load Using
3/16” Tempered Glass

@ 50 5/8” x 26 1/2” Window

+180 PSF/- 220 PSF

@ 63” x 37” Window

+110 PSF/-127 PSF

Cyclic Design Load
After Large Missile
Impact Using
KeepSafe Maximum®
Laminated Glass
(In Accordance with
Dade County Protocols
PA-201 & PA-203)

@ 50 5/8” x 26 1/2” Window

+110 PSF/-220 PSF

@ 63” x 37” Window

+110 PSF/-120 PSF

Forced Entry Test (AAMA 1302.5)

Passed

Refer to Miami-Dade County product approvals for performance on specific sizes.