For more information call 1.800.442.9042

TEST TYPE |
RESULTS |
|
|---|---|---|
Air Infiltration |
.07 CFM @ 6.24 PSF |
|
Maximum Water Resistance |
16.5 PSF |
|
Uniform Static Load Test |
@ 26 1/2” x 50 5/8” Window |
+180 PSF/- 220 PSF |
@ 37” x 63” Window |
+110 PSF/-127 PSF |
|
@ 48” x 72” Window |
+90 PSF/-102 PSF |
|
@ 54” x 120” Window |
+68 PSF/-76 PSF |
|
Cyclic Design Load |
@ 26 1/2” x 50 5/8” Window |
+110 PSF/-220 PSF |
@ 37” x 60” Window |
+110 PSF/-120 PSF |
|
@ 48” x 72” Window |
+90 PSF/-90 PSF |
|
@ 48” x 102” Window |
+70 PSF/-70 PSF |
|
@ 54” x 120” Window |
+50 PSF/-50 PSF |
|
Forced Entry Test (AAMA 1302.5) |
Passed |
|
TEST TYPE |
RESULTS |
|
|---|---|---|
Air Infiltration |
.02 CFM @ 6.24 PSF |
|
Maximum Water Resistance |
16.5 PSF |
|
Uniform Static Load Test |
@ 26 1/2” x 50 5/8” Window |
+180 PSF/- 220 PSF |
@ 37” x 63” Window |
+110 PSF/-127 PSF |
|
@ 48” x 72” Window |
+90 PSF/-102 PSF |
|
Cyclic Design Load |
@ 26 1/2” x 50 5/8” Window |
+110 PSF/-220 PSF |
@ 37” x 63” Window |
+110 PSF/-120 PSF |
|
@ 48” x 72” Window |
+90 PSF/-90 PSF |
|
Forced Entry Test (AAMA 1302.5) |
Passed |
|
Refer to Miami-Dade County product approvals for performance on specific sizes.